American DJ

collapse expand iconDescription

This cable features 22 AWG stranded (0.15 x 19) tinned copper conductors, polyethylene insulation, twisted pair, polyethylene inner jacket, Duofoil (100% coverage) and cotton plus a tinned copper braid shield (85% coverage). PVC jacket.
American DJ 3-Pin DMX Lighting Cable 3 ft.
warning

WARNING: This product can expose you to chemicals including Di(2-ethylhexyl)phthalate (DEHP), which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

collapse expand iconSpecs

Conductor
  • Number of Pairs: 1
  • Total Number of Conductors: 2
  • AWG: 22
  • Stranding: 0.15 x 19
  • Conductor Diameter: .0354"
  • Conduct or Material: TC-Tinned Copper
  • Insulation Material: PE Polyethylene
Lay Length
  • Lay Length: 2.5"
  • Direction: Left Hand Lay
  • Twists: 4.8 per foot
Inner Jacket
  • Inner Jacket Material: PE- Polyethylene
  • Inner Jacket Diameter: .055"
  • Pair Color Code: Black/White
Outer Shield
  • Outer Shield Trade Name: Duofoil
  • Outer Shield Type: Tape/Braid
Outer Shield Material
  • Layer 1: Material Trade Name--Duofoil, Type--Tape, Material--Aluminum Foil-Polyester, Coverage %--100
  • Layer 2: Material Trade Name--Duofoil, Type--Braid, Material--TC-Tinned Copper, Coverage %--85
  • Outer Jacket Material: PVC-Polyvinyl Chloride
  • Overall Nominal Diameter: .229"
  • Operating Temperature Range: -30 degrees C To + 75 degrees C
  • Bulk Cable Weight: 31 lbs./1000
  • Minimum Bend Radius (Install): 3.2"
  • Maximum Recommended Pull Tension: 72 lbs.
  • Nominal Characteristic Impedance: 110 Ohms
  • Nominal Capacitance Conductor to Conductor @ 1KHz: 12.8 pF/foot
  • Nominal Cap Cond. To Other Cond. & Shield @ 1KHz: 23 pF/foot
  • Nominal Velocity of Propagation: 66%
  • Nominal Delay: 1.6 nanoseconds per foot
  • Nominal Conductor DC Resistance @ 20 degrees C: 24 Ohms/1000 feet
  • Nominal Outer Shield D C Resistance @ 20 degrees C: 3.4 Ohms/ 1000 feet
  • Nominal Attenuation (dB/100 feet): 0.6 (@ 1 MHz) dB/100 feet
  • Maximum Recommended Current: 2.1 Amps per conductor @ 25 degree C

Featured Articles